- Overall size: 16.5” (W) x 16.5” (D) x 8.5” (H)
- Power ratings: 115V / 1 / 60 Hz, 0.75 Amp., Standby current is 7W only
- Washable Polypropylene core and MERV-3/4 Filters
- High efficiency, energy saving, permanently lubricated, backward inclined, non-overloading, variable speed PSC motors for air balancing
- Suitable for horizontal & vertical installation
- Tilted core design for maximum efficiency
- Automatic fan cycled defrost
- Exhaust up to 90 CFM
- Continuous fresh air supply up to 20-60 CFM
- Furnace / Fan-coil / Heat Pump Interlock
- Dual Protection: If exhaust fan fails, the outside fresh-air supply will be closed automatically (by optional motorized damper) and interlocking relay contact will be opened. Fan Coil/Furnace low speed will be stopped and at normal operation no air will enter into the system.
- Weight approximately 20 lbs.
- Washable MERV-3/4 filters.
- 2 years warranty on parts
Model# | Normal Speed Supply/Exhaust (Constant Ventilation) @ 50 Pa | High Speed Exhaust (Activated by switch) @ 50 Pa | Maximum Power Rating 120V / 1 / 60Hz |
---|---|---|---|
RERV-80 (Single Washroom) | 20~60 CFM variable | 60~90 CFM variable | 0.75 Amp |
RHRV-80P (Single Washroom) | 20~60 CFM variable | 60~90 CFM variable | 0.75 Amp |
* Normal and high speed can be adjusted by either installer or factory using speed controllers mounted on the main controller of the unit.
RHRV-80P | Supply Temperature | Net Airflow | Supply / Exhaust Flow Ratio | Average Power (Watts) | Sensible Recovery Efficiency | Apparent Sensible Effectiveness | Net Moisture Transfer | |||
---|---|---|---|---|---|---|---|---|---|---|
°C | °F | L/S | CFM | |||||||
Heating | I | 0 | 32 | 18 | 38 | 1.00 | 31 | 74 | 81 | 0.01 |
II | 0 | 32 | 22 | 47 | 1.02 | 33 | 72 | 79 | 0.02 | |
III | 0 | 32 | 30 | 64 | 1.02 | 39 | 70 | 74 | 0.01 | |
IV | -25 | -13 | 30 | 64 | 1.01 | 38 | 55 | 65 | 0.01 |
** Indicate Total Recovery Efficiency not Sensible Recovery Efficiency